Re: [DIYbio] Electronic requirements for redesign of Arduino PCR thermal cycler

On 02/27/2015 01:33 AM, Andy Morgan wrote:
> allowing me to run the whole thing off of just the one simple circuit described in the original instructable.
>
> Perhaps I'll look into using one peltier


Things can get complicated quickly. Think of how heat flows, and you'll see every time that
condensation is on things that lag the current air/sample-block temperature colder. When
air/sample-block is cooling down there is no problem. Peltier is complexity exxxtra. Lose it.

--
-- You received this message because you are subscribed to the Google Groups DIYbio group. To post to this group, send email to diybio@googlegroups.com. To unsubscribe from this group, send email to diybio+unsubscribe@googlegroups.com. For more options, visit this group at https://groups.google.com/d/forum/diybio?hl=en